Resumo

A control system can significantly improve the strength of structures to mitigate vibrations or their effects on the structure, keeping them within limits safe and meeting safety standards. One of the ways to promote this dampening of oscillations on the structure to be protected is the tuned liquid column damper (TLCD). This system promotes the damping of the structure’s oscillations through the oscillation of the liquid in a U-shaped reservoir, in which the liquid moves in opposition to the structure’s movement. The damping force is associated with the energy dissipation when the liquid passes through the orifice in its horizontal part. We take this non-conservative force with a linear dependence on the velocity. With this simplified model, we obtained analytical expressions for the description of the damping that is within the expected.

Downloads

Não há dados estatísticos.

Biografia do Autor

P. V. Brito dos Santos, Universidade do Estado do Rio de Janeiro

Researcher at Universidade do Estado do Rio de Janeiro.

A. C. de Castro Barbosa, Universidade do Estado do Rio de Janeiro

Researcher at Universidade do Estado do Rio de Janeiro.

M. V. Tovar Costa, Universidade do Estado do Rio de Janeiro

Researcher at Universidade do Estado do Rio de Janeiro.

A. L. de Oliveira, Instituto Federal do Rio de Janeiro

Researcher at Instituto Federal do Rio de Janeiro.

Referências

D.T. Custodio. “Utilização do elo de corrente contínua para o amortecimento de oscilações eletomecânicas em sistemas elétricos de potência”. Master dissertation. Unicamp, 2009.

R. M. Lima, L. F. Neiva, and W. M. Poubel. “Utilização do software de código aberto EMSO para oscilações de temperatura destinadas a análise de sua influência na taxa de reação de polimerização em suspensão de estireno”. In: Anais do XI Congresso Brasileiro de Engenharia Química em Iniciação Científica. 2015, pp. 2686–2690. doi: 10.5151/chemeng-cobeqic2015-203-32800-264233.

K.-W. Min, C.-S. Park, and K. Junhee. “Easy-to-tune reconfigurable liquid collumn vibration absorbers with multiple cells”. In: Smart Materials and Structures 24 (2015), p. 065041. doi: DOI10.1088/0964-1726/24/6/065041.

M.V.G. Morais, A.T. Fabro, and M.H. Alkmim. “Response variability with random uncertainty in tuned liquid column damper”. In: Revista interdisciplinar de pesquisa em engenharia (2016), pp. 1–11. doi: 10.26512/ripe.v2i16.21611.

S. S. Rao. Mechanical Vibrations. 5th ed. Boston: Pearson, 2011. isbn: 9780132128193.

M. A. Reis and S.A. Vitiello. “Método Variacional com Monte Carlo aplicado ao oscilador harmônico quântico”. In: Revista Brasileira de Ensino de Física 28 (2006), pp. 45–50. doi: https://doi.org/10.1590/S1806-11172006000100007.

F. Sadek and B. Mohraz. “Single-And Multiple-Tuned Liquid Column Dampers for Seismic Applications”. In: Earthquake engineering and structural dynamics 27 (1998), pp. 439–463. doi: https://doi.org/10.1002/(SICI)1096-9845(199805)27:5<439::AID-EQE730>3.0.CO;2-8.

F Sakai, S Takaeda, and T Tamaki. “Tuned liquid column damper - new type device for suppression of building vibrations”. In: Conference of Highrise building 2 (1989), pp. 926–931.

D. W. Vieira and A. S. Castro. “More on the quantum harmonic oscillator via unilateral Fourier transform”. In: Revista Brasileira de Ensino de Física 44 (2022), e202200381–4. doi: 10.1590/1806-9126-rbef-2022-0038.

J-C. C. Wu, Yuh-Yi Lin, and C-H. Chang. “Optimal designs for non-uniform tunned liquid column dampers in horizontal motion”. In: Journal of sound and vibrations 326 (2009), pp. 104–122. doi: doi:10.1016/j.jsv.2009.04.027.

S. K. Yalla and A. Kareem. “Optimum Absorver Parameters for Tuned Liquid Column Dampers”. In: Journal of Structural Engineering 24 (2000), pp. 906–9015. doi: DOI10.1088/0964-1726/24/6/065041.

Downloads

Publicado

2025-01-20

Edição

Seção

Trabalhos Completos